           Maxtor 7060S/7120S Jumper Designation And Parameters

                                      J20J19J18J17J16J15J14J13J11
Ĵ
 Master/Slave                                                   
  Only drive in single drive system*  J  J                      
  Master in dual drive system         J  O                      
  Slave in dual drive system          O  J                      
Ĵ
 ECC Bytes                                                      
  4 Bytes*                                  J                   
  7 Bytes                                   O                   
Ĵ
 Drive Model Number                                             
  7060A                                        O                
  7120A                                        J                
Ĵ
 Idle Mode Latch                                                
  Option Disabled*                                O             
  Option Enabled                                  J             
Ĵ
 Reserved for Factory                                           
  Normal Operation*                                  O          
  Factory Test Mode                                  J          
Ĵ
 Default Config @ Power Up                                      
           Cyls  Hds  Sec  MBytes                               
  Ĵ
  7060A    1024   7   17*   62.3               O        O  O    
            925   8   17    60.7               O        O  J    
            762   8   39    60.8               O        J  O    
            467  16   17    65.0               O        J  J    
  Ĵ
  7120A    1024  14   17*  124.7               J        O  O    
            900  15   17   117.5               J        O  J    
            762  16   17   121.7               J        J  O    
            936  16   17   130.3               J        J  J    
Ĵ
 I/O Channel Ready                                              
  Disabled*                                                   O 
  Enabled                                                     J 

  J=Jumpered O=Open *=Default
                                                              Ŀ       
                                                               J11    
                                              J20 J18 J16      J13    
                                             Ŀ     J14    
                                                        J15    
                                                              
                                                             
                                                J19 J17                   
                                           


/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\//\/\/\/\/\/\/\/\/\
                                                           
                                                        
                                                           
Ŀ  J602                                         J601    
    Ŀ                                         Ŀ    
    ..9-10                                     ..7-8 
  ܳ7-8                                      ..5-6 Ŀ
   ܳ5-6                                      ..3-4  
    ..3-4                                      ܳ1-2  
   ܳ1-2                                           
                                                       
                                                           
                                                           
                                                     
                     RP602            RP601                
                    .   .        
                               
                                                           
Ĵ
      J2                         J1                       

pin1             pin1

(Shown with Factory Default Jumper settings)

BASIC INSTALLATION STEPS

- Drive is shipped with an ID of 6 to provide spare jumpers.
  Choose address jumpers according to specific installation requirments.

- The last physical device on the SCSI bus must be terminated.
  Any other SCSI device connected between the host and the device at
  the end of the bus must NOT be terminated.

- Install a 50-pin ribbon connector. The striped edge of the 50-pin ribbon 
  cable represents pin 1 and must be oriented towards pin 1 at the drive 
  connector and the host connector.

- Install the DC power connector.

- Secure the drive in a bay with 6-32 x 1/4" screws.

- Set the drive type in the AT BIOS setup to "not installed". 
  Note: This intelligent drive will identify itself to the system and 
  SCSI host adaptor.

- The drive is now ready for partitioning and high-level formatting
  with any operating system. For example:

    Partition the drive using the FDISK program from MS-DOS 
    version 3.3 or higher.

    High-level format the drive using the FORMAT command from 
    MS-DOS version 3.3 or higher.

MFG

OS

ABC-Hotline
Billstr. 236
20539 Hamburg
per Fax
