           Maxtor 7040S/7080S Jumper Designation And Parameters


Ŀ
 Jumper    Pin                     Function                        
 Block   Location                                                  
Ĵ
  J601      -                   Terminator Power                   
Ĵ
  J603      -          Diagnostic Mode (factory Use only)          
Ĵ
  J604      -                      Reserved                        
Ĵ
  J605      -                    Disable Parity                    
Ĵ
  J602     1-2                   Power-up Option                   
Ĵ
  J602     3-4                       Not Used                      
Ĵ
  J602     5-6     Target ID Address (Most Significant Bit - MSB)  
Ĵ
  J602     7-8                  Target ID Address                  
Ĵ
  J602     9-10    Target ID Address (Least Significant Bit - LSB) 



     /\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\//\/\/\/\/\/\/\/\/\
                                                               
                                                             
                                                               
     Ŀ                                                       
                                                     Ŀ     
                                                     ..J604 
                                                   ..J605 Ŀ
                                                    ..J603  
                                                     ܳJ601  
                                                          
                                                                
                                                                
                                                              
                                                          
                         RP602               RP601            
                  .  .         
                             
             J602                                               
     ĺ    Ĵ
     1  J2      1                J1                       
         
            1 3 5 7 9
            | | | | |
            2 4 6 8 10

     (Shown with Factory Default Jumper Settings)


         Ŀ
          SCSI  Priority    J602       J602        J602   
           ID             Pins 5-6   Pins 7-8   Pins 9-10 
         Ĵ
           0     Lowest       O          O          O     
         Ĵ
           1                  O          O          J     
         Ĵ
           2                  O          J          O     
         Ĵ
           3                  O          J          J     
         Ĵ
           4                  J          O          O     
         Ĵ
           5                  J          O          J     
         Ĵ
           6                  J          J          O     
         Ĵ
           7    Highest       J          J          J     
         
         O=OPEN J=JUMPERED


BASIC INSTALLATION STEPS

- Drive is shipped with an ID of 6 to provide spare jumpers.
  Choose address jumpers according to specific installation requirments.

- The last physical device on the SCSI bus must be terminated.
  Any other SCSI device connected between the host and the device at
  the end of the bus must NOT be terminated.

- Install a 50-pin ribbon connector. The striped edge of the 50-pin ribbon 
  cable represents pin 1 and must be oriented towards pin 1 at the drive 
  connector and the host connector.

- Install the DC power connector.

- Secure the drive in a bay with 6-32 x 1/4" screws.

- Set the drive type in the AT BIOS setup to "not installed". 
  Note: This intelligent drive will identify itself to the system and 
  SCSI host adaptor.

- The drive is now ready for partitioning and high-level formatting
  with any operating system. For example:

    Partition the drive using the FDISK program from MS-DOS 
    version 3.3 or higher.

    High-level format the drive using the FORMAT command from 
    MS-DOS version 3.3 or higher.


MFG

OS

ABC-Hotline
Billstr. 236
20539 Hamburg
per Fax
