                  JUMPER SETTINGS FOR THE MAXTOR LXT-200S


DISK DRIVE SETUP (J-6)             SCSI ID. (PINS 1-6)      PINS        
----------------                   -------------------      ----          
                                                      5&6    3&4    1&2
------------------------------------------------------------------------------
PARITY ENABLE - PINS 9, 10         SCSI ADDRESS 0     OFF    OFF    OFF
MOTR. START   - PINS 7, 8          SCSI ADDRESS 1     OFF    OFF    ON
SCSI ADDRESS  - PINS 5, 6          SCSI ADDRESS 2     OFF    ON     OFF
SCSI ADDRESS  - PINS 3, 4          SCSI ADDRESS 3     OFF    ON     ON
SCSI ADDRESS  - PINS 1, 2          SCSI ADDRESS 4     ON     OFF    OFF
                                   SCSI ADDRESS 5     ON     OFF    ON
                                   SCSI ADDRESS 6     ON     ON     OFF
                                   SCSI ADDRESS 7     ON     ON     ON

J-6 PINS 7, 8             STATUS
-------------             ------
WAIT FOR START COMMAND     OFF
START WHEN POWER APPLIED   ON

NOTE: The LXT-200S is shipped from the factory with an ID of six (6)
This assures that sufficient jumpers are available for any address
except seven, wich is usually reserved for the host system.